Free Shipping on Orders Above $75 (US Only)
☎ (855) 586-4586

Input Requirement
ITEM  SPECIFICATION  MIN  TYP.  MAX 
NORMAL AC INPUT VOLTAGE  SINGLE PHASE  100Vac  100Vac/ 240Vac  240Vac 
AC INPUT VOLTAGE RANGE  SINGLE PHASE  90Vac  100Vac/ 240Vac  264Vac 
AC INPUT FREQUENCY  SINGLE PHASE  47Hz  50/60Hz  63Hz 
AC INPUT CURRENT  TYPICAL INPUT VOLTAGE& OUTPUT AT FULL LOAD.  800mA 
AC INRUSH CURRENT  TYPICAL INPUT VOLTAGE& OUTPUT AT FULL LOAD , 25Ž.  30A 
EFFICIENCY  TYPICAL INPUT VOLTAGE& OUTPUT AT FULL LOAD  89%  

 

Output Requirement
ITEM  SPECIFICATION  MIN  TYP.  MAX 
NORMAL DC OUTPUT VOLTAGE      12Vdc   
DC OUTPUT VOLTAGE RANGE  TYPICAL OUTPUT VOLTAGE }5%  11.4V  12.6V 
LOAD CURRENT RANGE  0A  8A 
PEAK LOAD CURRENT  TIME<60S  12A 
RIPPLE  TYPICAL INPUT VOLTAGE , TYPICAL LOAD CURRENT , 25Ž  120mV 
HOLD-UP TIME  AT TYPICAL INPUT VOLTAGE AND FULL LOAD  10mS   
TURN-ON DELAY  TYPICAL INPUT VOLTAGE AND TYPICAL LOAD CURRENT  3S 
OVER CURRENT PROTECTION  AUTO RECOVERY   
SHORT CIRCUIT PROTECTRON  THE ADAPTER SHALL NOT DAMAGE BY SHORT THE DC OUTPUT TO GROUND     

       
TYPICAL LOAD  AC INPUT AND TYPICAL LOAD IN OUTPUT  35 DEGREES   
  50/60Hz     
HI-POT TEST  BETWEEN INPUT&OUTPUT 3000Vac 60 SECONDS 10mA  NO DAMAGE   
IT IS BASE ON EN60950 5.2.2 TEST PROCEDURE.       
FOR MASS PRODUCTION, IT IS TESTED BY 3.3KV/1 SECOND.       
INSULATION RESISTANCE  INPUT TO OUTPUT,DC 500V  >100Mƒ¶   
MTBF  TYPICAL INPUT&FULL LOAD , 25Ž  50000 HOURS   
LIFE  TYPICAL INPUT&FULL LOAD, 40Ž  1YEARS ABOVE   
  TYPICAL INPUT&FULL LOAD, 25Ž  2YEARS ABOVE   
BURN-IN  AT 30Ž(}10Ž),NORMAL INPUT VOLTAGE  2~4 HOURS   
5.ENVIRONMENT       

         
ITEM  SPECIFICATION  MIN  TYP.  MAX 
OPERATING TEMPERATURE  0Ž  40Ž 
STORAGE TEMPERATURE  -20Ž  85Ž 
OPERATING HUMILITY  NON-CONDENSING  5%RH    90%RH 
STORAGE HUMILITY  NON-CONDENSING  5%RH    90%RH